Technical Data

ISO 20'¡¿8'¡¿6"

TYPE 0

TYPE 1

TYPE 2

TYPE 5

Capacity(litres)                        min.
 max.

17,000
28,000

13,000
26,000

17,000
28,000

13,000
26,000

Tare weight(kgs)                     min.
max.

2,200
3,000

3,500
6,000

2,500
3,300

 6,000
11,000

Tank thickness                        min.
max.

2§®
3§®

5.2§®
   8§®

3§®
4§®

6§®
20§® 

Working pressure                    min.
max.


1.75bar

   3bar
6.9bar


1.75bar

7bar
22bar 

  Safety device


valve

relief valve
burstingdisc


relief valve

relief valve
bursting disc

Insulation             Kcal/§³xhx¡É min.
max.

0.7
  0.17

0.7
   0.28 

0.7
   0.28 

0.7
   0.28 

Steam heating              surface min.
max.

1.5§³
   2§³

2.5§³
 16§³

2.5§³
   5§³

-

Electrical heating           power min.
max.

  9§Ò
12§Ò

  9§Ò
24§Ò

 7§Ò
12§Ò 

-

Operating temperature              min.
max.

 -20¡É
+120¡É 

 -20¡É
+120¡É 

  -20¡É
+120¡É

-40¡É
+55¡É/+60¡É 

  NON ISO
  Capacity(liters)
  2,000m¡¿ 2,438m¡¿2,591m(1/3 20')
  6,058m¡¿ 2,500m¡¿2,591m
  7,150m¡¿2,500m¡¿2,591m
  9,120m¡¿2,500m¡¿2,591m 



-
26,300
29,500
32,500



  5,700
26,300
29,500
   32,500* 



  5,700
26,300
29,500
  32,500*



-
-
-
-

(*)Type 4


Head Office : 6, 7F KAS B/D, 44-1, World Cup buk-ro, Mapo-gu, Seoul, Republic of Korea
Copyright ©2003-2006 KAS TANK CONTAINER SERVICES LTD. All rights reserved. Designed by Easymedia.